Vibrating Wire Strain Gauges for Bridge, Tunnel & Dam Monitoring: Complete Selection Guide
The global construction industry is experiencing a massive surge in large-scale infrastr...

Load Cells with Data Logger for Reliable Measurement
In geotechnical instrumentation, capturing load data over time is often what separates a risky guess from an informed decision. A load cell with a data logger streamlines this process by recording measurements directly at the sensor, reducing cable runs and simplifying field setups. Kingmach manufactures load cells designed to work seamlessly with our data loggers, covering everything from anchor force checks to pile load tests. The combination means you don’t have to match components from different suppliers or worry about signal mismatch. Our engineers configure the logger to the specific load cell output, so the unit arrives ready to deploy. This integration is particularly practical on remote slopes, underground excavations, or structural monitoring jobs where reliable unattended recording matters. Rather than chasing fragmented solutions, teams get a single package that handles the sensing and the logging without extra adapters or calibration guesswork.
Technical Detail
Kingmach’s load cells with data loggers are built for field environments where consistent performance and straightforward data retrieval count. The load cells come in common geotechnical ranges, from low-capacity soil pressure cells to high-tonnage anchor load cells, each paired with a logger that matches the sensor’s excitation and signal type. Analog inputs accept 4–20 mA, mV/V, or voltage signals, so you can connect string pots, displacement transducers, or other sensors alongside the load cell if needed. Logging intervals are adjustable—anything from once per second for dynamic tests to once per hour for long-term monitoring—helping balance data density against battery life. Data typically saves to internal flash memory, with options to retrieve it via USB cable, wireless modules, or a straightforward mobile app. Power comes from internal batteries or external solar setups for extended runs. We calibrate each load cell with its paired logger to keep readings accurate across the temperature range you specify. The hardware is housed in weatherproof enclosures rated for outdoor use, and mounting brackets are included for attachment to the load cell or a nearby structure. Because Kingmach handles both the sensor and the electronics, technical support covers the whole system, not just half of it. Custom configurations, like additional sensor channels or specific communication protocols, are available when a standard logger doesn’t quite fit the project.
News

The global construction industry is experiencing a massive surge in large-scale infrastr...

Cable-stayed bridges, pre-stressed concrete decks, and dam anchors rely on precisely cal...

The Type of Load Cell Is Not a Product Choice—It Is an Engineering Decision In ...
Products

Earth Pressure Cell ( VW & Smart Type) JMZX-50XXAT/ ATM
View Details
Wide-Range Smart Differential Pressure Water Level Meter JMYC-67XXAD
View Details
Large Earth Pressure Cell ( VW & Smart Type) JMZX-51XXAT/ ATM
View DetailsFAQ
Yes. Most of our data loggers accept multiple analog inputs. If your load cell uses a 4–20 mA output, you can often connect a displacement sensor on a second channel as long as the signal types are compatible. Let us know what you’re planning, and we can check the channel configuration.
Standard retrieval is via USB to a laptop. For remote sites, we offer wireless options—commonly 4G or LoRa modules—that push data to a server. Some teams prefer to visit the site periodically and download data with a mobile app over Bluetooth. We can help you choose what works best for your site access and data frequency needs.
Yes, we calibrate them together before shipping. The logger is configured with the load cell’s specific sensitivity and zero balance, so you don’t need to enter those values in the field. A calibration certificate is included, though for critical applications you may want to verify on site with known loads.
It depends on the logging interval and sensor excitation. With a once-per-hour sampling rate and internal batteries, you might get several months. Adding solar panels extends this further. We can estimate based on your logging plan—just share the target interval and sensor count.
Some of our loggers support SMS or email alerts when configured with a wireless module. You would set a threshold for the load cell channel, and the logger checks periodically. It’s not available on every model, so mention this during the inquiry if it’s important for your project.
Share your product type, target capacity, and application requirements. Our team can review the details and recommend a practical next step.
If you are interested in our products or want to become our partner.
Please leave your contact information, our team will contact you as soon as possible.
Mail: [email protected]
Contact Us: +8613808434127
Address: No. 188 Tongzipo West Rd, Changsha, Hunan, China